Posted by Wayne Howell on 08 June 2013 08:42 AM

In order to make a product visible in DMX-Workshop, the product must reply to an ArtPoll with one or more ArtPollReply. The attached file shows a Wire Shark capture of the ArtPollReply packets from a Data-Lynx IOP.

Common errors in formatting ArtPollReply are:

1) The text signature at the top of the packet is "Art-Net". It is case sensitive.

2) DMX-Workshop only listens on Port 6454 (decimal).

If you have difficulty making your product visible in DMX-Workshop then post a (small) Wire Shark capture on this forum and we will try to help.